AlcoAudit


The AlcoAudit personal breathalyser uses Fuel Cell Technology (like the police) to measure the concentration of alcohol vapor on expired breath. The AlcoAudit is extremely easy to operate, simply press the “On/Off” button to turn the unit on, press the “On/Off” button once again to go into test mode, attach a mouthpiece and blow. The reading will then be displayed.


The main advantage of the AlcoAudit is the use of the Fuel Cell. Fuel Cell’s are used in industrial breath analysers to give RELIABLE and ACCURATE results! Most personal breathalysers use Semi-conductor type sensors which do not give consistent results and only have a short life span.


The AlcoAudit breathalyzer also offers a data logging facility with a memory capacity of 4000 tests. Every test performed has the date, time and BAC concentration recorded in the internal memory. This data can uploaded to a computer and viewed on an Excel spreadsheet. The user can analyse the data to obtain information regarding their use of the unit such as, how often it is being used, what are the average readings as well as monitor the performance of the unit.


ADT can calibrate the AlcoAudit as per the requirements of the customer. We recommend 6 monthly calibrations on units used 2-3 times per week. If the unit is being using in social situations where a lot of people are using the AlcoAudit calibration should be more frequent.


The AlcoAudit is the perfect instrument for conducting personal breath tests morning or night. Don’t get caught drink driving on your way home from the pub or on your way to work in the morning, the AlcoAudit can help you determine whether you are over the limit or whether your BAC (Blood Alcohol Concentration) is rising or falling. Most people don’t realize if you wake up hung over there is most likely alcohol still in your system. This is why the police have RBT’s setup at 8 o’clock in the morning, not to catch people who like to have a beer with breakfast but to catch people with alcohol still in their system from the night before.

 

Price: $ 385.00 Including GST

Postage: $14.90 

Availability: In stock

                                                                     

 

 

To purchase mouthpieces please see our Breathalyser Accessories page.

 

AlcoAudit Technical Specifications

Details

Technical data

Principle of measurements

Electrochemical/fuel cell sensor, alcohol specific

Measurement range (BrAC)

0.000mg/L1.500mg/L

Resolution

0.0001 mg/L

Accuracy: Max. Measure error, in relation to ethanol standard

Ethanol Vapor Concentration

C /(mg/L)

Deviation

C<0.400

±0.020mg/L

0.400≤C<1.000

±5%

C≥1.000

±20%

Repeatability of Indicating Value

Ethanol Vapor Concentration

C /(mg/L)

Deviation

C<0.400

0.007mg/L

0.400≤C<1.000

1.75%

C≥1.000

6%

Calibration

Every 6 months

Temperature Range-Operation

5℃45℃

Temperature Range-Storage

20℃70℃

Optimum Storage Condition

Temperature 20℃±5, Humidity: <80%RH, Pressure: 86kPa~106kPa, No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device.

Blowing Time

3 seconds (breath flow20L/min)

Warm-up Time

Less than 5 seconds after switching on

Recovery Time

5 seconds to 5 minutes, depends on Ethanol Vapor Concentration

Analysis Time

Less than 10 seconds

Display

 128×64 dot matrix black and white screen

Dimensions

Approx. 127mm×60mm×28mm

Memory

4096 records

Operation Voltage

State of Charging

State of Operation

5 V

DC 3.64.2V

Battery

Built-in 1000mAh/3.7V Li-ion polymerized battery

Weight

Approx. 115g